Size: | |
---|---|
Material: | |
Availability: | |
Quantity: | |
P/PU-90 150 260
BOLV (ZHICHU )
The six-sided heating system ensures the high-temperature uniformity.
Infrared CO2 sensor can automatically compensate based on the temperature and pressure, etc., with high reliability.
The dry heat sterilization system of 160 ℃ - 180 ℃ can completely sterilize products. All parts in the box do not need to be disassembled, and one-click sterilization operation is convenient.(only model P-90A/B 150A/B 260A/B)
The UV sterilization of air duct can timely purify the air inside the box, without affecting the culture during sterilization, and the UV lamp is convenient for replacement.(only model PU-90A/B 150A/B 260A/B)
The unique dual circulation air duct design has non-natural convection, ensuring high uniformity of temperature, humidity and CO2 concentration within the box.
Naturally humidifies via water plate.(A series)
A programmable cyclic damp heat test humidifier for humidification.(B series)
The six-sided heating system ensures the high-temperature uniformity.
Infrared CO2 sensor can automatically compensate based on the temperature and pressure, etc., with high reliability.
The dry heat sterilization system of 160 ℃ - 180 ℃ can completely sterilize products. All parts in the box do not need to be disassembled, and one-click sterilization operation is convenient.(only model P-90A/B 150A/B 260A/B)
The UV sterilization of air duct can timely purify the air inside the box, without affecting the culture during sterilization, and the UV lamp is convenient for replacement.(only model PU-90A/B 150A/B 260A/B)
The unique dual circulation air duct design has non-natural convection, ensuring high uniformity of temperature, humidity and CO2 concentration within the box.
Naturally humidifies via water plate.(A series)
A programmable cyclic damp heat test humidifier for humidification.(B series)
Model | P-90A / B PU-90A / B | P-150A / B PU-150A / B | P-260A / B PU-260A / B |
Supply voltage | AC220V/50Hz | AC220V/50Hz | AC220V/50Hz |
Input power | 1300W | 1300W | 1300W |
Operating ambient temperature | 19℃-25℃ | 19℃-25℃ | 19℃-25℃ |
Display screen | 4.3-inch color touch screen | ||
Volume of box | 106L | 175L | 300L |
Temperature control range | R.T.+5 ℃ - 55 ℃(@25℃) | ||
Temperature display accuracy | ±0.1(37℃) | ±0.1(37℃) | ±0.1(37℃) |
Temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ |
Temperature uniformity | ± 0.3 (37 ℃, R.T. 25 ℃) | ± 0.3 (37 ℃, R.T. 25 ℃) | ± 0.3 (37 ℃, R.T. 25 ℃) |
Temperature control mode | PID microcomputer control | ||
CO2 range | 0%-20% | 0%-20% | 0%-20% |
CO2 control accuracy | ±0.1%(5%,37℃) | ±0.1%(5%,37℃) | ±0.1%(5%,37℃) |
CO2 resolution | 0.1% | 0.1% | 0.1% |
CO2 sensor | Infrared CO2 sensor with automatic compensation based on temperature and pressure, etc. | ||
CO2 control | PID microcomputer control | ||
Natural humidification | A series | A series | A series |
Volume of water pan | 1500ml | 2500ml | 4150ml |
Automatic humidity control via humidifier | B series | B series | B series |
Humidity control range | Ambient humidity: -98%RH | ||
Humidity control accuracy | ≤ ± 2% (at 37 ℃) | ||
Humidity resolution | 0.1% | ||
Humidity recovery time | Open the door for 1 minute, and and the humidity will be recovered within the standard requirements within 25 minutes after closing the door | ||
Volume of water storage tank | 1L | 1L | 1L |
Inner material | SUS304 Antibacterial stainless steel | ||
Number of inner shelves | Standard configured 3nos | Standard configured 3nos | Standard configured 4nos |
Interior dimensions | W450×D450×H550mm | W540×D560×H580mm | W600×D560×H900mm |
External dimensions | W590×D630×H890mm | W680×D715×H900mm | W730×D715×H1220mm |
Model | P-90A / B PU-90A / B | P-150A / B PU-150A / B | P-260A / B PU-260A / B |
Supply voltage | AC220V/50Hz | AC220V/50Hz | AC220V/50Hz |
Input power | 1300W | 1300W | 1300W |
Operating ambient temperature | 19℃-25℃ | 19℃-25℃ | 19℃-25℃ |
Display screen | 4.3-inch color touch screen | ||
Volume of box | 106L | 175L | 300L |
Temperature control range | R.T.+5 ℃ - 55 ℃(@25℃) | ||
Temperature display accuracy | ±0.1(37℃) | ±0.1(37℃) | ±0.1(37℃) |
Temperature resolution | 0.1℃ | 0.1℃ | 0.1℃ |
Temperature uniformity | ± 0.3 (37 ℃, R.T. 25 ℃) | ± 0.3 (37 ℃, R.T. 25 ℃) | ± 0.3 (37 ℃, R.T. 25 ℃) |
Temperature control mode | PID microcomputer control | ||
CO2 range | 0%-20% | 0%-20% | 0%-20% |
CO2 control accuracy | ±0.1%(5%,37℃) | ±0.1%(5%,37℃) | ±0.1%(5%,37℃) |
CO2 resolution | 0.1% | 0.1% | 0.1% |
CO2 sensor | Infrared CO2 sensor with automatic compensation based on temperature and pressure, etc. | ||
CO2 control | PID microcomputer control | ||
Natural humidification | A series | A series | A series |
Volume of water pan | 1500ml | 2500ml | 4150ml |
Automatic humidity control via humidifier | B series | B series | B series |
Humidity control range | Ambient humidity: -98%RH | ||
Humidity control accuracy | ≤ ± 2% (at 37 ℃) | ||
Humidity resolution | 0.1% | ||
Humidity recovery time | Open the door for 1 minute, and and the humidity will be recovered within the standard requirements within 25 minutes after closing the door | ||
Volume of water storage tank | 1L | 1L | 1L |
Inner material | SUS304 Antibacterial stainless steel | ||
Number of inner shelves | Standard configured 3nos | Standard configured 3nos | Standard configured 4nos |
Interior dimensions | W450×D450×H550mm | W540×D560×H580mm | W600×D560×H900mm |
External dimensions | W590×D630×H890mm | W680×D715×H900mm | W730×D715×H1220mm |