The six-sided heating system ensures the high-temperature uniformity.
The second-generation infrared CO2 sensor can automatically compensate based on the temperature and pressure, etc., with high reliability.
The dry heat sterilization system of 160 ℃ - 180 ℃ can completely sterilize products. All parts in the box do not need to be disassembled, and one-click sterilization operation is convenient.
The unique dual circulation air duct design has non-natural convection, ensuring high uniformity of temperature, humidity and CO2 concentration within the box.
A programmable cyclic damp heat test humidifier is adopted to humidify rapidly.(Model P-90WB)
It can be stacked in two layers, three layers and mixed layers.
Model | P-90WA | P-90WB |
Supply voltage | AC220V/50Hz | AC220V/50Hz |
Input power | 1300W | 1300W |
Operating ambient temperature | 19℃-25℃ | 19℃-25℃ |
Display screen | 4.3-inch touch screen | |
Volume of box | 106L | 106L |
Temperature control range | R.T.+3℃-55℃ | R.T.+5℃-55℃ |
Temperature display accuracy | ±0.1(37℃) | ±0.1(37℃) |
Temperature resolution | 0.1℃ | 0.1℃ |
Temperature uniformity | ± 0.3 (37 ℃, R.T. 25 ℃) | ± 0.3 (37 ℃, R.T. 25 ℃) |
Temperature control mode | PID microcomputer control | PID microcomputer control |
CO2 range | 0%-20% | 0%-20% |
CO2 control accuracy | ±0.1%(5%,37℃) | ±0.1%(5%,37℃) |
CO2 resolution | 0.1% | 0.1% |
CO2 sensor | Infrared CO2 sensor with automatic compensation based on temperature and pressure, etc. | Infrared CO2 sensor with automatic compensation based on temperature and pressure, etc. |
CO2 control | PID microcomputer control | PID microcomputer control |
Humidity Control | Naturally humidifies via water plate, and can be upgraded to a programmable cyclic damp heat test humidifier for humidification | A programmable cyclic damp heat test humidifier is equipped |
Inner material | Antibacterial stainless steel | Antibacterial stainless steel |
Number of inner shelf | Standard configured 2 pieces | Standard configured 2 pieces |
Dimension of inner incubator | W498×D500×H398mm | W498×D500×H398mm |
External dimensions | W800×D690×H516mm | W800×D690×H516mm |
Humidity control range | Ambient humidity 98%RH | Ambient humidity 98%RH |
Humidity control accuracy | ≤ ± 2% (at 37 ℃) | ≤ ± 2% (at 37 ℃) |
Humidity resolution | 0.1% | 0.1% |
Humidity recovery time | / | Open the door for 1 minute, and and the humidity will be recovered within the standard requirements within 25 minutes after closing the door |
| 1L | 1L |